Lamont gauges
Magnamont™ · Fortimag™ · Polysight™
The model code identifies the float: the material at position 05 and the specific gravity at position 06.
Transmitters and switches
Level bridles and chambers
Level bridlesBridles and external chambersSS316, engineered to orderRetrofits and spare parts
Product selection
Send the fluid, specific gravity, design pressure and temperature, and centre-to-centre dimension. Lamont Controls Engineering recommends the gauge.
Request a quotationDocumentationCookies on this site
Analytics, advertising measurement and session recording stay off unless accepted. They show how the site is used and which advertising brings enquiries. The choice can be changed at any time under Cookie settings at the foot of each page. Privacy policy
Lamont Controls supplies replacement MagnaLine™ floats for Magnamont™, Fortimag™ and Polysight™ magnetic level gauges, and floats matched to the existing chamber for gauges of other makes. Each float is selected for the chamber bore, the fluid's specific gravity at operating temperature, and the design pressure and temperature. Where the chamber is sound, a new float can often return a gauge to service without a complete replacement. Order by the model code or serial number on the gauge nameplate, or send a nameplate photo with the chamber size. Lamont Controls Engineering confirms the float and the fit at quotation.
Model code positions 05 and 06
Replacement
The float rides the liquid surface and carries the magnet that turns the indicator flags. It is replaced when it can no longer follow the level, or when the fluid in service has changed.
Inspect the float before ordering. The cause can change the specification: a crushed float points to pressure, a stuck float to solids or debris.
Selection
| Parameter | Requirement |
|---|---|
| Chamber boreSize and schedule |
The float must fit the chamber's inside diameter. The bore is set by the chamber size and its schedule or wall thickness: a heavier wall holds more pressure but leaves a smaller bore. Lamont chambers are 1.5 and 2 in on Magnamont™; 1.5 and 2 in on Fortimag™, with 2.5 in for Class 1500; and 2 in on Polysight™. Float dimensions are supplied with the quotation. |
| Specific gravityPosition 06 |
The float is weighted to the fluid's SG at operating temperature, and its own SG must be lower than the fluid's. Most liquids get lighter as they warm: a float weighted for a cold SG sits deeper in hot service and reads low. Minimum SG 0.34 (Magnamont™, Fortimag™) and 0.59 (Polysight™). |
| PressureDesign pressure |
A hollow float is loaded from the outside. It is weighted to the operating pressure and rated for the design pressure. Ball-segment and syntactic-foam floats are engineered for the highest pressures. |
| TemperatureFloat material |
The float material sets a temperature limit. Polysight™ floats are rated to 176 °F (80 °C) in polypropylene, 212 °F (100 °C) in PVDF and 248 °F (120 °C) in PTFE. Magnamont™ and Fortimag™ floats are rated for the operating temperature; the rating is confirmed at quotation. |
| Magnetic couplingInstalled indicator |
The float's magnet turns the indicator flags through the chamber wall, so a replacement float must couple with the indicator installed on the gauge. The float is installed with its orientation arrow pointing up; a float installed upside down couples poorly. |
Fit, materials and ratings are confirmed at quotation.
How the float drives the indicator: Principle of operation
Request
Float replacement on a magnetic level gauge starts with the nameplate and the chamber. Send these details with the request; for several gauges, list each tag or attach a tag list. Lamont Controls Engineering selects the float and confirms the part and the fit in the quotation.
MagnaLine™ floats
| Float | Options |
|---|---|
| Metal floatsMagnamont™ · Fortimag™ |
Ball-segment and syntactic-foam floats are engineered per application; consult factory. VaporGuard™ flashing-service float protection (option VG) is available on Fortimag™ only. |
| Thermoplastic floatsPolysight™ |
Chamber limit: CPVC about 199 °F (93 °C), PVDF about 248 °F (120 °C), service-dependent. The float rating can limit the gauge below the chamber limit. |
The float is a wetted part. Lamont states the wetted materials; the user confirms their compatibility with the fluid, its concentration and temperature.


Lamont gauges · other makes
Magnamont™ · Fortimag™ · Polysight™
The model code identifies the float: the material at position 05 and the specific gravity at position 06.
Matched to the existing chamber
Lamont Controls Engineering cross-references the existing float to a MagnaLine™ replacement float, matched to the existing chamber, the fluid's specific gravity and the operating conditions. The match is made from the details sent with the request. Lamont Controls supplies a float only where it fits the chamber.
Built to the existing connections
Where the chamber is damaged, or a significant change in operating conditions calls for a different gauge, a replacement Magnamont™, Fortimag™ or Polysight™ gauge is built to the existing centre-to-centre and process connections.
Questions
Yes. Lamont Controls Engineering cross-references the existing float to a MagnaLine™ replacement float, matched to the existing chamber, the fluid's specific gravity and the operating conditions. The quotation confirms the part and the fit. Lamont Controls supplies a float only where it fits the chamber.
The model code or serial number from the gauge nameplate, or a nameplate photo. For another make, add the existing part number or the make and model, the chamber size and schedule, the fluid and its specific gravity at operating temperature, and the design pressure and temperature. Photos of the installed gauge help confirm the fit.
The fluid's SG at normal operating temperature, and the range it moves through. Most liquids get lighter as they warm, so a float weighted for a cold SG reads low in hot service. For an interface between two liquids, give both SGs.
SG 0.34 on Magnamont™ and Fortimag™, and 0.59 on Polysight™; the float's SG must be lower than the fluid's. On Magnamont™, consult the factory below SG 0.45, and for two-phase or solids-bearing service.
No. Remove the float before any hydrostatic test of the gauge or vessel, and install it after the test is complete.
No. The float ships in its own packaging, never inside the chamber. MagnaLine™ floats carry an orientation arrow: install the float with the arrow pointing up.
When the chamber is damaged, or when a significant change in operating conditions calls for a different gauge. A replacement Magnamont™, Fortimag™ or Polysight™ gauge is built to the existing centre-to-centre and process connections. See Retrofits.
Quotation
Enter the model code or serial number from the gauge nameplate, or attach a photo of the nameplate.
For a gauge of another make, add the existing part number, the chamber size and schedule, and the process details.
What happens nextLamont Controls Engineering confirms the part and replies within 1 to 3 business days with a quotation or with questions.
1-833-7LAMONT info@lamontcontrols.com