MagnaLine titanium float standing upright, magnet end at the top, engraved with an upward arrow and the Lamont Controls mark
MagnaLine™ titanium float
Orientation arrow up

Replacement floats for magnetic level gauges

Lamont Controls supplies replacement MagnaLine™ floats for Magnamont™, Fortimag™ and Polysight™ magnetic level gauges, and floats matched to the existing chamber for gauges of other makes. Each float is selected for the chamber bore, the fluid's specific gravity at operating temperature, and the design pressure and temperature. Where the chamber is sound, a new float can often return a gauge to service without a complete replacement. Order by the model code or serial number on the gauge nameplate, or send a nameplate photo with the chamber size. Lamont Controls Engineering confirms the float and the fit at quotation.

Standard float
TitaniumMagnamont™ and Fortimag™
Minimum SG
0.34Magnamont™ and Fortimag™; Polysight™ 0.59
Polysight™ floats
PTFE · PVDF · PPTo 248 °F (120 °C), by material
Lamont chamber sizes
1.5 · 2 · 2.5 in2.5 in on Fortimag™, Class 1500

Model code positions 05 and 06

Replacement

When a float is replaced

Float only, where the chamber is sound

The float rides the liquid surface and carries the magnet that turns the indicator flags. It is replaced when it can no longer follow the level, or when the fluid in service has changed.

Inspect the float before ordering. The cause can change the specification: a crushed float points to pressure, a stuck float to solids or debris.

  • Collapsed or flooded. A float that has collapsed under pressure or taken in liquid loses buoyancy and sinks to the bottom of the chamber.
  • Dented or damaged. A float dropped or struck during handling can lose buoyancy, or develop rough edges that drag on the chamber wall.
  • Weakened magnet. The magnet is sealed inside the float, so a float with a weakened magnet is replaced as a unit.
  • New fluid or new SG. The float is weighted for the fluid's specific gravity. If the SG changes significantly, the float is replaced with one weighted for the new conditions.
  • Stuck float. Debris, sediment or scale can hold a float in place; clean the float and the chamber first. Viscous, waxy or solids-bearing service needs a float engineered for it.

Selection

Float sizing and fit

ParameterRequirement
Chamber boreSize and schedule

The float must fit the chamber's inside diameter. The bore is set by the chamber size and its schedule or wall thickness: a heavier wall holds more pressure but leaves a smaller bore. Lamont chambers are 1.5 and 2 in on Magnamont™; 1.5 and 2 in on Fortimag™, with 2.5 in for Class 1500; and 2 in on Polysight™.

Float dimensions are supplied with the quotation.

Specific gravityPosition 06

The float is weighted to the fluid's SG at operating temperature, and its own SG must be lower than the fluid's. Most liquids get lighter as they warm: a float weighted for a cold SG sits deeper in hot service and reads low.

Minimum SG 0.34 (Magnamont™, Fortimag™) and 0.59 (Polysight™).

PressureDesign pressure

A hollow float is loaded from the outside. It is weighted to the operating pressure and rated for the design pressure. Ball-segment and syntactic-foam floats are engineered for the highest pressures.

TemperatureFloat material

The float material sets a temperature limit. Polysight™ floats are rated to 176 °F (80 °C) in polypropylene, 212 °F (100 °C) in PVDF and 248 °F (120 °C) in PTFE. Magnamont™ and Fortimag™ floats are rated for the operating temperature; the rating is confirmed at quotation.

Magnetic couplingInstalled indicator

The float's magnet turns the indicator flags through the chamber wall, so a replacement float must couple with the indicator installed on the gauge. The float is installed with its orientation arrow pointing up; a float installed upside down couples poorly.

Fit, materials and ratings are confirmed at quotation.

How the float drives the indicator: Principle of operation
Render at the liquid level: the float's magnet ring in the chamber and the indicator flags turning beside the scale
Render · Magnamont™ at the liquid level: the float's magnet ring inside the chamber, and the indicator flags turning beside the scale.

Request

What to send

Float replacement on a magnetic level gauge starts with the nameplate and the chamber. Send these details with the request; for several gauges, list each tag or attach a tag list. Lamont Controls Engineering selects the float and confirms the part and the fit in the quotation.

  1. Nameplate. A photo of the gauge nameplate, or the model code or serial number. For another make, the make and model, or the existing float part number.
  2. Chamber. The chamber size and schedule, or its inside diameter, and the chamber material.
  3. Fluid. The fluid and its specific gravity at operating temperature, with the range it moves through. For interface service, the SG of both liquids.
  4. Pressure and temperature. The design pressure and temperature, and the operating conditions.
  5. Photos. The installed gauge and its indicator, and the old float, with its length and diameter where known.

MagnaLine™ floats

Float materials

FloatOptions
Metal floatsMagnamont™ · Fortimag™
  • Titanium TI: standard, weighted to the fluid's SG and operating pressure
  • 316 stainless steel SS: optional, for heavier fluids and general industrial service
  • Ball-segment: spherical geometry resists external collapse, for the highest pressure classes; titanium or stainless
  • Syntactic foam: a solid buoyant core with no cavity to collapse, for extreme-pressure service; moderate-temperature service
  • Coated, lined and exotic-alloy floats CU: consult factory

Ball-segment and syntactic-foam floats are engineered per application; consult factory. VaporGuard™ flashing-service float protection (option VG) is available on Fortimag™ only.

Thermoplastic floatsPolysight™
  • PTFE TF: standard with a CPVC chamber · SG > 0.84 · to 248 °F (120 °C) · low-pressure service, consult factory
  • PVDF PV: standard with a PVDF chamber · SG > 0.79 · to 212 °F (100 °C)
  • Polypropylene PP: optional · SG > 0.59 · to 176 °F (80 °C)
  • Custom CU: coated floats, alternative thermoplastics, exotic alloys and interface-service designs; consult factory

Chamber limit: CPVC about 199 °F (93 °C), PVDF about 248 °F (120 °C), service-dependent. The float rating can limit the gauge below the chamber limit.

The float is a wetted part. Lamont states the wetted materials; the user confirms their compatibility with the fluid, its concentration and temperature.

Four MagnaLine floats standing upright: titanium engraved with the Lamont Controls mark, syntactic foam, PTFE and solid thermoplastic
MagnaLine™ floats, left to right: titanium, engraved with the Lamont Controls mark and the orientation arrow; syntactic foam; PTFE; solid thermoplastic. Not to scale.
MagnaLine solid PTFE float for a Polysight gauge, upright with the magnet end at the top
MagnaLine™ solid PTFE float for Polysight™.

Lamont gauges · other makes

Floats for Lamont gauges and other makes

Lamont gauges

Magnamont™ · Fortimag™ · Polysight™

The model code identifies the float: the material at position 05 and the specific gravity at position 06.

Magnamont™Fortimag™Polysight™

Gauges of other makes

Matched to the existing chamber

Lamont Controls Engineering cross-references the existing float to a MagnaLine™ replacement float, matched to the existing chamber, the fluid's specific gravity and the operating conditions. The match is made from the details sent with the request. Lamont Controls supplies a float only where it fits the chamber.

Indicators and scales: Spare parts

Replace the whole gauge

Built to the existing connections

Where the chamber is damaged, or a significant change in operating conditions calls for a different gauge, a replacement Magnamont™, Fortimag™ or Polysight™ gauge is built to the existing centre-to-centre and process connections.

Retrofits

Questions

Replacement float questions

Can Lamont supply a replacement float for a magnetic level indicator of another make?

Yes. Lamont Controls Engineering cross-references the existing float to a MagnaLine™ replacement float, matched to the existing chamber, the fluid's specific gravity and the operating conditions. The quotation confirms the part and the fit. Lamont Controls supplies a float only where it fits the chamber.

What is needed to quote a replacement float?

The model code or serial number from the gauge nameplate, or a nameplate photo. For another make, add the existing part number or the make and model, the chamber size and schedule, the fluid and its specific gravity at operating temperature, and the design pressure and temperature. Photos of the installed gauge help confirm the fit.

What SG should be given for the float?

The fluid's SG at normal operating temperature, and the range it moves through. Most liquids get lighter as they warm, so a float weighted for a cold SG reads low in hot service. For an interface between two liquids, give both SGs.

What is the minimum specific gravity?

SG 0.34 on Magnamont™ and Fortimag™, and 0.59 on Polysight™; the float's SG must be lower than the fluid's. On Magnamont™, consult the factory below SG 0.45, and for two-phase or solids-bearing service.

Does the float stay in the chamber for a hydrostatic test?

No. Remove the float before any hydrostatic test of the gauge or vessel, and install it after the test is complete.

Is the float shipped inside the chamber?

No. The float ships in its own packaging, never inside the chamber. MagnaLine™ floats carry an orientation arrow: install the float with the arrow pointing up.

When should the whole gauge be replaced instead?

When the chamber is damaged, or when a significant change in operating conditions calls for a different gauge. A replacement Magnamont™, Fortimag™ or Polysight™ gauge is built to the existing centre-to-centre and process connections. See Retrofits.

Quotation

Order a replacement float

Enter the model code or serial number from the gauge nameplate, or attach a photo of the nameplate.

For a gauge of another make, add the existing part number, the chamber size and schedule, and the process details.

What happens nextLamont Controls Engineering confirms the part and replies within 1 to 3 business days with a quotation or with questions.

1-833-7LAMONT info@lamontcontrols.com

Full quotation form

Fields marked * are required.

Gauge *
Parts needed *

SurePoint™ switches are supplied for Lamont gauges only.

Contact

Your email address is used for communications related to this request. You may unsubscribe at any time. Lamont Controls Inc., 800–120 Eglinton Ave E, Toronto, ON M4P 1E2, Canada · info@lamontcontrols.com.

Submissions are reviewed by Lamont Controls Engineering.By sending this form you agree to the Terms of use. See the Privacy policy.
Request a quotation Call