Analytics, advertising measurement and session recording stay off unless accepted. They show how the site is used and which advertising brings enquiries. The choice can be changed at any time under Cookie settings at the foot of each page. Privacy policyAnalytics, advertising measurement and session recording stay off unless accepted. They show how the site is used and which advertising brings enquiries. The choice can be changed at any time under Cookie settings at the foot of each page. Privacy policyThis site uses analytics and advertising cookies to show how it is used and which advertising brings enquiries. Decline turns them off. Session recording runs only after Accept. The choice can be changed at any time under Cookie settings at the foot of each page. Privacy policy
Side–side · CPVC chamber Flanged connections · PVC flag indicator
Polysight™ CPVC and PVDF magnetic level gauge
Designed for acids, caustics and salts in chemical storage tanks, water and wastewater treatment, and OEM skid systems. The thermoplastic chamber has no glass and, with a standard non-metallic float, no metal in the wetted path. The indicator mounts outside the chamber, isolated from the process. Each gauge is engineered to order for the chemistry, the vessel and the fluid's specific gravity.
Pressure
150 psigfull vacuum to 10 bar
Temperature
−4…+248 °F−20…+120 °C
C-C length, standard to
18.5 ft222 in (5,640 mm)
Minimum SG
0.59float weighted for the fluid
Made in Canada
Construction
Front view
The float travels in a 2 in thermoplastic chamber, CPVC or PVDF, with solvent- and fusion-bonded joints. The indicator mounts outside the chamber and has no contact with the process.
Shown
Side–side configuration
C-C
44.8 in (1,138 mm)
Chamber
CPVC
Connections
Flanged, 2 in, ANSI 150
Indicator
ClearView™ IPVC-80, no scale
Flanged side connection beside the Lamont nameplatePVC flags in a transparent PVC housingBolted bottom flangeThreaded drain below the bottom flange
1VentThreaded FNPT or MNPT, ½ to 1 in
2Process connectionsFlanged, FNPT or MNPT; 1 to 2 in (3 in: consult factory); ANSI 150
3IndicatorClearView™ PVC flags, magnetically coupled to the float
4MagnaLine™ floatPTFE, PVDF or PP, weighted for the fluid; floats at the liquid level
5Chamber2 in CPVC (standard) or PVDF
6Bottom flange and drainBolted flange; threaded drain, ½ to 1 in
FIG. 02 · Polysight, side–side, CPVC, 44.8 in centre-to-centre: side view left, front view right. A MagnaLine™ PTFE float is shown at the liquid level, where the flags change from white to red.
Product
Design features
Thermoplastic wetted path. CPVC or PVDF, selected for the process chemistry. Both resist the acids, alkalis and salts that corrode metal.
No glass in the pressure boundary. A sealed thermoplastic chamber replaces the sight glass. The gauge has no glass to break under thermal shock or impact.
Automation without new nozzles. LevelSync™ and SurePoint™ clamp to the outside of the chamber.
Testing. Pressure tested before shipment; hydrostatic test at not less than 1.5 × design pressure and a 24-hour water-fill leak test where specified. Test certificates available.
CPVC chambers, PVC flag indicators and flanged side connections.
Production photographs
NameplateRatings and body material above the bottom flangeIndicatorPVC flags change from white to red at the liquid levelSide connectionFlanged thermoplastic connection beside the nameplate
Operation
Principle of operation
Indicator · float · magnetic coupling · indication
Flags at the liquid level
Float. A sealed MagnaLine™ float carries a permanent magnetic assembly. The float is weighted for the fluid's specific gravity and floats at the liquid surface. As the level rises or falls, the float moves with it inside the sealed thermoplastic chamber.
Magnetic coupling. The float's magnetic field couples through the chamber wall to the ClearView™ indicator mounted outside the chamber. The indicator follows the float and shows the level without contact with the process.
Visual indication. The indicator is a column of rotating flags, in PVC or stainless steel to suit the service temperature. Each flag turns as the float passes: one colour shows liquid below, the other vapour above. The reading is continuous. There is no glass in the pressure boundary and no wetted electronics, and the construction reduces potential leak paths.
Also available: HS-80. Hermetically sealed, argon-filled; condensation- and fog-proof · 176 °F (80 °C). Gauges are also supplied without an indicator (IX), for transmitter-only or switch-only service.
IPVC-80 is recommended for corrosive fumes; HS-80 for condensation, humidity or washdown.
Solid PTFE for hydrochloric acid and aggressive reducing service. SG > 0.84, to 248 °F (120 °C); low-pressure service, consult factory.
PVDF (PV)Standard, PVDF chamber
PVDF fluoropolymer for aggressive and high-purity chemistry. SG > 0.79, to 212 °F (100 °C).
Polypropylene (PP)Optional
Solid polypropylene for general corrosive service. SG > 0.59, to 176 °F (80 °C).
Custom (CU)Consult factory
Coated floats, alternative thermoplastics, exotic alloys and interface-service designs.
Minimum SG 0.59. Each float is precision-weighted for the fluid's specific gravity, subject to float design and application conditions.
Automation
LevelSync™ transmitters and SurePoint™ switches
LevelSync™ · SurePoint™
LevelSync™ transmitters and SurePoint™ switches are externally mounted and magnetically coupled to the gauge’s MagnaLine™ float. They have no wetted parts, require no additional vessel nozzle, and are fitted at the factory or in the field.
LevelSync™
Magnetostrictive level transmitter
Continuous level output from the gauge float by magnetostrictive time-of-flight sensing. No moving parts and no routine recalibration.
Output
4–20 mA with HART®; Modbus RTU or DDA optional
Accuracy
±0.039 in (±1 mm) inherent
Length
12 to 144 in (305 to 3,658 mm); longer on request
Process temp.
To 302 °F (150 °C), standard mounting
Hazardous area
Intrinsically safe or explosionproof; FM, FMc, ATEX, IECEx, UKCA
Housing
Epoxy-coated aluminum or 316L stainless; NEMA 4X, IP65
Order with option MLT in the gauge model code.
SurePoint™
Magnetic point-level switch
Leverless switch actuated by the float's magnet for high and low level alarms and basic control. No moving levers and no actuation power.
Contact
SPDT, latching
Rating
Up to 25 W resistive; 1 A at 24 VDC; 150 VDC · 230 VAC max
Hazardous area
Class I, Div. 1 (UL 1203); Class II, Groups E, F, G; gas groups confirmed at quotation
Switch temp.
−58 to +221 °F (−50 to +105 °C)
Housing
300-series stainless steel, factory sealed
Mounting
Band clamp; set point adjustable along the chamber
Temperature. SurePoint™ switches are rated to 221 °F (105 °C); above that, consult factory.
Hazardous-area certifications are held by Lamont's component manufacturing partner and apply to the supplied product. Final certification, temperature class and marking depend on configuration and are confirmed at quotation.
Feet and inches · metres / cm · percent · gallons or litres to tank volume · custom · none
Testing and documentation
Inspection
Visual inspection of solvent- and fusion-bonded joints and the assembly
Pressure test
Pressure tested before shipment; hydrostatic test with clean water at not less than 1.5 × design pressure (1 hour minimum) where specified
Leak test
Where specified, a 24-hour water-fill test after the hydrostatic test; no visible leakage or weeping
Documentation
Test certificates available
Further inspection
Available on request, where applicable
Options
FloatSense™ float-integrity monitoring (FS)
Specified in the model code; none (NF) is the default.
Interface service (INT)
Float set for the second liquid's SG, specified in the model code.
Custom options (X)
Engineered to the application, on request.
Ratings. Pressure and temperature ratings depend on materials, connections and configuration, and are confirmed at quotation.
Custom configurations. Special chamber sizes, custom or exotic materials and custom process connections on request. Contact Lamont Controls Engineering.
Quality
Quality, testing and documentation
Build and test sequence · documents
01
Approval drawing
Issued after the purchase order. The design is confirmed on the drawing before fabrication starts.
02
Fabrication
Industrial grade (IG) thermoplastic fabrication; solvent- and fusion-bonded joints.
03
Inspection
Visual inspection of solvent- and fusion-bonded joints and the assembly.
04
Pressure test
Pressure tested before shipment; hydrostatic test with clean water at not less than 1.5 × design pressure (1 hour minimum) where specified.
05
Leak test
Where specified, a 24-hour water-fill test after the hydrostatic test; no visible leakage or weeping.
06
Float and indicator
The float is precision-weighted for the fluid’s specific gravity. The indicator mounts outside the chamber.
Documents
Test certificates
Available
Approval drawing
Issued after the purchase order
Certificate of origin
Chamber-of-commerce certified, on request
Further inspection
Available on request, where applicable
Quotation
Request a quotation
Complete the process conditions below, or attach a datasheet or drawing. Fields marked * are required. Process data speeds up the quotation.
For a general enquiry, select Quick message and provide your contact details with a brief note.
For a replacement, attach a photo of the existing nameplate and enter the centre-to-centre dimension.
LAMONT CONTROLS ENGINEERING · SENT AFTER REVIEWDimensional drawingsOutline drawings for the standard Polysight™ configurations, one sheet each: side–side, top–bottom, top–side, bottom–side and top-mount. Sent by Lamont Controls Engineering after review; final dimensions are on the approval drawing, issued after the purchase order.
Water-treatment and chemical-dosing skids. One approved drawing covers a production run.
Also serving pools and recreational water · irrigation and fertigation · odour-control and scrubber chemistry · electroplating job shops · laboratory and specialty chemicals. For a metal gauge at higher pressure or temperature, see Magnamont™; for extreme pressure and temperature, see Fortimag™.