Lamont Controls 1-833-7LAMONT Request a quotation Call

Cookies on this site

Analytics, advertising measurement and session recording stay off unless accepted. They show how the site is used and which advertising brings enquiries. The choice can be changed at any time under Cookie settings at the foot of each page. Privacy policy

Polysight magnetic level gauge, full length: grey CPVC chamber in side–side configuration with flanged process connections, a threaded vent on top, a bolted bottom flange with a threaded drain, and a transparent PVC indicator with white and red flags
Side–side · CPVC chamber
Flanged connections · PVC flag indicator

Polysight™ CPVC and PVDF magnetic level gauge

Designed for acids, caustics and salts in chemical storage tanks, water and wastewater treatment, and OEM skid systems. The thermoplastic chamber has no glass and, with a standard non-metallic float, no metal in the wetted path. The indicator mounts outside the chamber, isolated from the process. Each gauge is engineered to order for the chemistry, the vessel and the fluid's specific gravity.

Pressure
150 psigfull vacuum to 10 bar
Temperature
−4…+248 °F−20…+120 °C
C-C length, standard to
18.5 ft222 in (5,640 mm)
Minimum SG
0.59float weighted for the fluid

Made in Canada

Construction

Front view

The float travels in a 2 in thermoplastic chamber, CPVC or PVDF, with solvent- and fusion-bonded joints. The indicator mounts outside the chamber and has no contact with the process.

Shown
Side–side configuration
C-C
44.8 in (1,138 mm)
Chamber
CPVC
Connections
Flanged, 2 in, ANSI 150
Indicator
ClearView™ IPVC-80, no scale
Lamont Controls nameplate on a grey CPVC Polysight chamber, with a flanged side process connection behind it
Flanged side connection beside the Lamont nameplate
Red PVC indicator flags in a transparent PVC housing, banded to the chamber above the nameplate
PVC flags in a transparent PVC housing
Bolted thermoplastic bottom flange on a Polysight chamber, with the drain fitting below
Bolted bottom flange
Threaded thermoplastic drain fitting below the bottom flange of a Polysight gauge
Threaded drain below the bottom flange
Polysight magnetic level gauge, side view: two flanged side connections, grey CPVC chamber, transparent indicator housing, bolted bottom flange and threaded drain The same Polysight gauge, front view: transparent PVC indicator with white flags above the liquid level and red flags below, threaded vent on top, flanged connections behind the chamber MagnaLine PTFE float, upright with the magnet end at the top
1VentThreaded FNPT or MNPT, ½ to 1 in
2Process connectionsFlanged, FNPT or MNPT; 1 to 2 in (3 in: consult factory); ANSI 150
3IndicatorClearView™ PVC flags, magnetically coupled to the float
4MagnaLine™ floatPTFE, PVDF or PP, weighted for the fluid; floats at the liquid level
5Chamber2 in CPVC (standard) or PVDF
6Bottom flange and drainBolted flange; threaded drain, ½ to 1 in
FIG. 02 · Polysight, side–side, CPVC, 44.8 in centre-to-centre: side view left, front view right. A MagnaLine™ PTFE float is shown at the liquid level, where the flags change from white to red.

Product

Design features

  • Thermoplastic wetted path. CPVC or PVDF, selected for the process chemistry. Both resist the acids, alkalis and salts that corrode metal.
  • No glass in the pressure boundary. A sealed thermoplastic chamber replaces the sight glass. The gauge has no glass to break under thermal shock or impact.
  • Automation without new nozzles. LevelSync™ and SurePoint™ clamp to the outside of the chamber.
  • Testing. Pressure tested before shipment; hydrostatic test at not less than 1.5 × design pressure and a 24-hour water-fill leak test where specified. Test certificates available.
Two Polysight gauges: grey CPVC chambers, transparent PVC indicators with red flags, flanged side connections and Lamont nameplates
CPVC chambers, PVC flag indicators and flanged side connections.

Production photographs

Lamont Controls nameplate on a grey CPVC Polysight chamber, above the bolted thermoplastic bottom flange
NameplateRatings and body material above the bottom flange
Polysight ClearView indicator at the liquid level, seen straight on: white flags above, red flags below, in the transparent PVC housing
IndicatorPVC flags change from white to red at the liquid level
Polysight chamber with red indicator flags, the Lamont nameplate and a flanged thermoplastic side connection
Side connectionFlanged thermoplastic connection beside the nameplate

Operation

Principle of operation

Polysight indicator at the liquid level: white flags above, red flags below, beside the grey CPVC chamber
Flags at the liquid level
  1. Float. A sealed MagnaLine™ float carries a permanent magnetic assembly. The float is weighted for the fluid's specific gravity and floats at the liquid surface. As the level rises or falls, the float moves with it inside the sealed thermoplastic chamber.
  2. Magnetic coupling. The float's magnetic field couples through the chamber wall to the ClearView™ indicator mounted outside the chamber. The indicator follows the float and shows the level without contact with the process.
  3. Visual indication. The indicator is a column of rotating flags, in PVC or stainless steel to suit the service temperature. Each flag turns as the float passes: one colour shows liquid below, the other vapour above. The reading is continuous. There is no glass in the pressure boundary and no wetted electronics, and the construction reduces potential leak paths.

How a magnetic level gauge works: full principle of operation

Options

Indicators and floats

ClearView™ indicators

ClearView IPVC-80 indicator: white and red PVC flags in a transparent PVC housing, beside a grey CPVC chamber
IPVC-80Standard
PVC flags, transparent PVC housing · 176 °F (80 °C)
ClearView IPVC-120 indicator: red PVC flags beside a scale graduated in inches
IPVC-120PVC flags, aluminum housing with scale · 248 °F (120 °C)
ClearView ISFS-300 indicator: red flags beside a black etched aluminum scale
ISFS-300Stainless flags, aluminum housing with scale · rated 572 °F (300 °C); gauge limit 248 °F (120 °C)

Also available: HS-80. Hermetically sealed, argon-filled; condensation- and fog-proof · 176 °F (80 °C). Gauges are also supplied without an indicator (IX), for transmitter-only or switch-only service.

IPVC-80 is recommended for corrosive fumes; HS-80 for condensation, humidity or washdown.

MagnaLine™ floats

MagnaLine solid PTFE float, upright with the magnet end at the top
PTFE (TF)Solid PTFE float
MagnaLine solid thermoplastic float, upright
ThermoplasticSolid thermoplastic float
  • PTFE (TF)Standard, CPVC chamber

    Solid PTFE for hydrochloric acid and aggressive reducing service. SG > 0.84, to 248 °F (120 °C); low-pressure service, consult factory.

  • PVDF (PV)Standard, PVDF chamber

    PVDF fluoropolymer for aggressive and high-purity chemistry. SG > 0.79, to 212 °F (100 °C).

  • Polypropylene (PP)Optional

    Solid polypropylene for general corrosive service. SG > 0.59, to 176 °F (80 °C).

  • Custom (CU)Consult factory

    Coated floats, alternative thermoplastics, exotic alloys and interface-service designs.

Minimum SG 0.59. Each float is precision-weighted for the fluid's specific gravity, subject to float design and application conditions.

Automation

LevelSync™ transmitters and SurePoint™ switches

LevelSync™ transmitters and SurePoint™ switches are externally mounted and magnetically coupled to the gauge’s MagnaLine™ float. They have no wetted parts, require no additional vessel nozzle, and are fitted at the factory or in the field.

LevelSync transmitter with a blue display head, mounted on the side of a gauge chamber below a bolted top flange

LevelSync™

Magnetostrictive level transmitter

Continuous level output from the gauge float by magnetostrictive time-of-flight sensing. No moving parts and no routine recalibration.

Output
4–20 mA with HART®; Modbus RTU or DDA optional
Accuracy
±0.039 in (±1 mm) inherent
Length
12 to 144 in (305 to 3,658 mm); longer on request
Process temp.
To 302 °F (150 °C), standard mounting
Hazardous area
Intrinsically safe or explosionproof; FM, FMc, ATEX, IECEx, UKCA
Housing
Epoxy-coated aluminum or 316L stainless; NEMA 4X, IP65

Order with option MLT in the gauge model code.

Two SurePoint magnetically actuated level switches with colour-coded leads

SurePoint™

Magnetic point-level switch

Leverless switch actuated by the float's magnet for high and low level alarms and basic control. No moving levers and no actuation power.

Contact
SPDT, latching
Rating
Up to 25 W resistive; 1 A at 24 VDC; 150 VDC · 230 VAC max
Hazardous area
Class I, Div. 1 (UL 1203); Class II, Groups E, F, G; gas groups confirmed at quotation
Switch temp.
−58 to +221 °F (−50 to +105 °C)
Housing
300-series stainless steel, factory sealed
Mounting
Band clamp; set point adjustable along the chamber

Order 1 to 8 switches with option PLS-1 to PLS-8.

Include LevelSync™ or SurePoint™ in the quotation

Temperature. SurePoint™ switches are rated to 221 °F (105 °C); above that, consult factory.

Hazardous-area certifications are held by Lamont's component manufacturing partner and apply to the supplied product. Final certification, temperature class and marking depend on configuration and are confirmed at quotation.

Data

Technical specifications

Ratings

PressureFull vacuum to 150 psig (10 bar)
Temperature−4 to +248 °F (−20 to +120 °C)
Chamber limitCPVC ~199 °F (~93 °C) · PVDF ~248 °F (~120 °C)
Float limitPP 176 °F (80 °C) · PVDF 212 °F (100 °C) · PTFE 248 °F (120 °C)
Measuring rangeStandard lengths to 18.5 ft (222 in, 5,640 mm) centre-to-centre; longer lengths on request
AccuracyTypical ±0.4 in (±10 mm)
Specific gravity0.59 minimum

Construction

ConfigurationsSide–side (standard) · top–bottom · top–side · bottom–side · top-mount
Chamber size2 in; schedule and material per design. Custom sizes (SP) on request
Chamber materialCPVC (standard) · PVDF · custom or exotic (CC): consult factory
ConstructionIndustrial grade (IG) thermoplastic fabrication; solvent- and fusion-bonded joints
Surface finishNatural (standard) · painted, on CPVC only, for outdoor / UV service

Connections

Process connectionsFlanged; threaded (FNPT / MNPT). 1, 1½ and 2 in (standard 2 in); 3 in: consult factory; DN25 to DN50 and 25A to 50A on request; custom (CS) on request
Flange classesANSI 150 (standard) · DIN PN10 · JIS 5K on request
Vent and drainThreaded FNPT (standard) or MNPT; ½ (standard), ¾ or 1 in; flanged: consult factory; or none

Indication

IndicatorsClearView™ IPVC-80 (standard) · IPVC-120 · ISFS-300 · HS-80 · none (IX)
ScalesFeet and inches · metres / cm · percent · gallons or litres to tank volume · custom · none

Testing and documentation

InspectionVisual inspection of solvent- and fusion-bonded joints and the assembly
Pressure testPressure tested before shipment; hydrostatic test with clean water at not less than 1.5 × design pressure (1 hour minimum) where specified
Leak testWhere specified, a 24-hour water-fill test after the hydrostatic test; no visible leakage or weeping
DocumentationTest certificates available
Further inspectionAvailable on request, where applicable

Options

FloatSense™ float-integrity monitoring (FS)Specified in the model code; none (NF) is the default.
Interface service (INT)Float set for the second liquid's SG, specified in the model code.
Custom options (X)Engineered to the application, on request.
  • Ratings. Pressure and temperature ratings depend on materials, connections and configuration, and are confirmed at quotation.
  • Custom configurations. Special chamber sizes, custom or exotic materials and custom process connections on request. Contact Lamont Controls Engineering.

Quality

Quality, testing and documentation

  1. 01

    Approval drawing

    Issued after the purchase order. The design is confirmed on the drawing before fabrication starts.

  2. 02

    Fabrication

    Industrial grade (IG) thermoplastic fabrication; solvent- and fusion-bonded joints.

  3. 03

    Inspection

    Visual inspection of solvent- and fusion-bonded joints and the assembly.

  4. 04

    Pressure test

    Pressure tested before shipment; hydrostatic test with clean water at not less than 1.5 × design pressure (1 hour minimum) where specified.

  5. 05

    Leak test

    Where specified, a 24-hour water-fill test after the hydrostatic test; no visible leakage or weeping.

  6. 06

    Float and indicator

    The float is precision-weighted for the fluid’s specific gravity. The indicator mounts outside the chamber.

Documents

Test certificates
Available
Approval drawing
Issued after the purchase order
Certificate of origin
Chamber-of-commerce certified, on request
Further inspection
Available on request, where applicable

Quotation

Request a quotation

Complete the process conditions below, or attach a datasheet or drawing. Fields marked * are required. Process data speeds up the quotation.

For a general enquiry, select Quick message and provide your contact details with a brief note.

For a replacement, attach a photo of the existing nameplate and enter the centre-to-centre dimension.

Alternatively, complete the fillable quote request form (PDF) and return it by email.

What happens nextLamont Controls Engineering reviews the conditions and replies within 1 to 3 business days with a quotation.

1-833-7LAMONT info@lamontcontrols.com

Provide your contact details and a brief message. Lamont Controls Engineering replies within 1 to 3 business days.

Attach the datasheet, drawing or P&ID and enter your contact details. Lamont Controls Engineering takes the conditions from the file and replies with a quotation or with questions.

A datasheet, drawing, P&ID or nameplate photo can replace the gauge fields: attach it and they become optional.

Process data (optional, speeds up the quotation)

Contact

Submissions are reviewed by Lamont Controls Engineering.By sending this form you agree to the Terms of use. See the Privacy policy.

Downloads

Documentation

Document access

Enter your business email address to download the product brochure, technical specification sheet and model code reference.

Your email address is used for communications related to this request. You may unsubscribe at any time. Lamont Controls Inc., 800–120 Eglinton Ave E, Toronto, ON M4P 1E2, Canada · info@lamontcontrols.com.

Cover of PS-BR-010, Polysight product brochure, November 2026PS-BR-010 · NOVEMBER 2026Product brochure13 pages · 1.8 MB PDFDownload
Cover of PS-TS-010, Polysight technical specification sheet, November 2026PS-TS-010 · NOVEMBER 2026Technical specification sheet2 pages · 302 KB PDFDownload
Cover of PS-MC-010, Polysight model code reference, November 2026PS-MC-010 · NOVEMBER 2026Model code reference3 pages · 462 KB PDFDownload
Cover of LC-QR-010, the fillable MLG quote request formLC-QR-010 · NOVEMBER 2026Quote request form1 page · 82 KB · fillable PDFDownload
Outline drawing sheet, Polysight, sent on requestOn request
LAMONT CONTROLS ENGINEERING · SENT AFTER REVIEWDimensional drawingsOutline drawings for the standard Polysight™ configurations, one sheet each: side–side, top–bottom, top–side, bottom–side and top-mount. Sent by Lamont Controls Engineering after review; final dimensions are on the approval drawing, issued after the purchase order.
Request drawings

Guides. How to specify a magnetic level gauge · Installation best practices · Troubleshooting

Applications

Industries served

Chemical processing and storage

Sulfuric and hydrochloric acid, caustics and sodium hypochlorite in day tanks, storage tanks and batch systems.

Chemical storage tanks

Water and wastewater treatment

Chemical feed and dosing (hypochlorite, alum, polymer, ferric chloride), filtration and disinfection skids.

Chemical storage tanks

Seawater and desalination

RO trains, intake and brine service, and coastal installations exposed to chloride attack.

Chlor-alkali and bleach chemistry

Chlorine-side chemistry, hypochlorite generation and HCl handling. Chambers are engineered for oxidizing service.

Chemical storage tanks

Metal finishing and surface treatment

Level indication at the tank for plating baths, pickling acids and anodizing lines.

Mining and hydrometallurgy

Acid leach solutions, electrolyte circuits and reagent storage.

Pulp and paper bleaching

Bleach-plant chemistry and chemical storage.

Semiconductor and high-purity chemicals

PVDF construction for aggressive and high-purity chemical distribution, with no metal ions in the wetted path.

Demineralized and ultrapure water

DI and polished-water systems that specify plastic wetted parts.

Food, beverage and CIP chemistry

Caustic and acid CIP solution storage and dosing. The gauge is sealed, glass-free and washdown-tolerant.

Aquaculture and marine systems

Seawater loops and treatment systems, onshore and shipboard.

Marine tanks

OEM dosing and treatment skids

Water-treatment and chemical-dosing skids. One approved drawing covers a production run.

Also serving pools and recreational water · irrigation and fertigation · odour-control and scrubber chemistry · electroplating job shops · laboratory and specialty chemicals. For a metal gauge at higher pressure or temperature, see Magnamont™; for extreme pressure and temperature, see Fortimag™.

Request a quotation Call