Magnamont magnetic level gauge, full length: side–side with Weldolet process connections, an access flange on top for a low-clearance installation, black etched scale and red and white indicator flags
Side–side · Weldolet connections
Custom top access flange · low clearance

Magnamont™ Magnetic level gauge

A 316 stainless steel magnetic level gauge for storage tanks, process vessels, boilers, drums and utility skids. The welded chamber isolates the indicator from the process and reduces potential leak paths. There is no glass in the pressure boundary and no wetted electronics. Each gauge is engineered to order for the vessel, the fluid and the piping code specified. High-contrast indicator flags show the level at a distance.

Pressure
3,400 psigfull vacuum to 234 bar
Temperature
−40…+842 °F−40…+450 °C
C-C length, standard to
18.5 ft222 in (5,640 mm)
Minimum SG
0.34float weighted for the fluid

Made in Canada

Construction

Front and side view

The welded 316 stainless steel chamber contains the float. The indicator and scale mount outside the chamber and have no contact with the process.

Shown
Side–side configuration
C-C
48 in (1,219 mm)
Connections
Flanged
Indicator
ClearView™ flags, scale in feet and inches
Float
MagnaLine™ titanium
Top of a Magnamont chamber: threaded vent plug in the welded end cap, with the process nozzle weld below
1Vent plug in the welded end cap
Flanged process connection on a welded nozzle, beside the etched aluminum scale at the 4 ft mark
2Flanged process connection on a welded nozzle
Black etched aluminum scale at the 3 ft mark; the indicator flags are white above the liquid level and red below it
3Black etched scale; flags turn red below the level
Bottom of a black etched scale: the Lamont Controls mark etched at 0 ft beside red indicator flags, with the gauge nameplate on the chamber below
4Indicator flags beside the Lamont mark at 0 ft
Magnamont magnetic level gauge, front view: scale in feet and inches beside red and white indicator flags, flanged process connections behind the chamber The same Magnamont gauge, side view: two flanged side connections, welded chamber, indicator housing and bolted bottom flange MagnaLine titanium float, upright with the magnet end at the top: Lamont Controls marking and an upward orientation arrow
1VentThreaded ⅛ to 1 in; flanged ½ to 1 in
2Process connectionsFlanged, threaded or welded; ½ to 4 in
3ScaleEtched aluminum; imperial, metric, percent or volume
4IndicatorClearView™ flags, magnetically coupled to the float
5MagnaLine™ floatTitanium, weighted for the fluid; floats at the liquid level
6ChamberWelded SS316; other alloys on request
7Bottom flangeBolted; drain connection per model code
FIG. 02 · Magnamont, side–side, 48 in centre-to-centre: front view left, side view right. The float is shown at the liquid level, where the flags change from white to red.

Configurations

Process connection configurations

Renders · dimensions per application
Render of a Magnamont gauge, side–side configuration: two flanged side process connections, vent at the top, drain at the bottom, indicator alongside
Side–sideStandard. Process connections on the side of the chamber, top and bottom.
Render of a Magnamont gauge, top–bottom configuration: flanged process connections at the top and bottom ends, indicator alongside
Top–bottomFlanged process connections on the top and bottom ends of the chamber.
Render of a Magnamont gauge, top–side configuration: a flanged connection at the top end and a flanged side connection at the bottom, indicator alongside
Top–sideOne process connection on the top end, one on the side at the bottom.
Render of a Magnamont gauge, bottom–side configuration: a flanged side connection at the top and a flanged connection at the bottom end, indicator alongside
Bottom–sideOne process connection on the bottom end, one on the side at the top.
Render of a Magnamont gauge, top-mount configuration: a single flanged process connection at the bottom for mounting on the vessel top, indicator alongside
Top-mountChamber and indicator on a single flanged connection on the vessel top.

Product

Design features

  • Piping code construction. Heavy-duty schedule pipe; ASME B31.1 or B31.3 construction, or industrial grade.
  • Automation without new nozzles. LevelSync™ and SurePoint™ clamp to the outside of the chamber.
  • Visible at a distance. High-contrast flags are isolated from the process and do not cloud or stain.
  • No glass in the pressure boundary. A welded, all-metal bypass chamber replaces the glass assembly.
Top of a Magnamont gauge: vent plug in the welded end cap, flanged process connection on a welded nozzle, and the etched aluminum scale at 4 ft
Vent plug, end-cap weld and flanged process connection.

Production photographs

Socket-weld branch outlet welded to the side of a 316 stainless steel Magnamont chamber, chamber vertical: the socket bore and the weld bead round its base
Socket-weld branch outletOutlet welded to the chamber
Etched aluminum scale beside red indicator flags, banded to the chamber above a flanged side connection
Scale and flagsEtched scale and indicator, banded to the chamber
ClearView ISFS-300 indicator, straight on: white flags above the liquid level and red flags below, beside the black etched aluminum scale
Black etched scaleISFS-300 standard indicator: red flags beside the black etched aluminum scale

Operation

Principle of operation

Cutaway render of a Magnamont gauge: half-section of the chamber with the MagnaLine float and its magnet at the liquid surface, and the ClearView indicator beside it, flags white above the level and red below. Section B–B is marked at the float magnet.
Cutaway · render, 30 in (762 mm) C-C
Animation · the cutaway beside it follows its level by percent of range
  1. Float. A sealed MagnaLine™ float carries a permanent magnetic assembly. The float is weighted for the fluid's specific gravity and floats at the liquid surface. As the level rises or falls, the float moves with it inside the chamber.
  2. Magnetic coupling. The float's magnetic field couples through the chamber wall to the ClearView™ indicator mounted outside the chamber. The indicator follows the float and shows the level without contact with the process.
  3. Visual indication. The indicator is a column of rotating flags in contrasting colours. Each flag turns as the float passes: one colour shows liquid below, the other vapour above. The reading is continuous.

How a magnetic level gauge works: full principle of operation

Options

Indicators and floats

ClearView™ indicators

ClearView ISFS-300 indicator: red flags beside a black etched aluminum scale
ISFS-300Standard
Stainless flags, aluminum housing with scale · 572 °F (300 °C)
ClearView ISF-300 indicator: a column of red flags in an aluminum housing with no scale
ISF-300Stainless flags, aluminum housing, no scale · 572 °F (300 °C)
ClearView IAF-450 indicator: white and red flags beside an etched aluminum scale at the 2 ft mark
IAF-450High-temperature aluminum flags, with scale · 842 °F (450 °C)

Also available: HS-300. Hermetically sealed, argon-filled indicator in a stainless housing with scale · 572 °F (300 °C).

MagnaLine™ floats

Four MagnaLine floats standing upright: titanium engraved with the Lamont Controls mark, syntactic foam, PTFE and solid thermoplastic
  • TitaniumStandard

    Titanium, precision-weighted for the fluid's specific gravity and operating pressure.

  • 316 stainless steelOptional

    316/316L stainless steel for heavier fluids and general industrial service.

  • Engineered and customConsult factory

    High-pressure ball-segment, syntactic foam for extreme-pressure service, exotic alloys, coated and lined floats.

Minimum SG 0.34; the float's SG must be lower than the fluid's. Consult factory below SG 0.45 or for two-phase or solids-bearing service.

Automation

LevelSync™ transmitters and SurePoint™ switches

LevelSync™ transmitters and SurePoint™ switches are externally mounted and magnetically coupled to the gauge’s MagnaLine™ float. They have no wetted parts, require no additional vessel nozzle, and are fitted at the factory or in the field.

LevelSync transmitter with a blue display head, mounted on the side of a gauge chamber below a bolted top flange

LevelSync™

Magnetostrictive level transmitter

Continuous level output from the gauge float by magnetostrictive time-of-flight sensing. No moving parts and no routine recalibration.

Output
4–20 mA with HART®; Modbus RTU or DDA optional
Accuracy
±0.039 in (±1 mm) inherent
Length
12 to 144 in (305 to 3,658 mm); longer on request
Process temp.
To 302 °F (150 °C); to 527 °F (275 °C) with thermal standoff
Hazardous area
Intrinsically safe or explosionproof; FM, FMc, ATEX, IECEx, UKCA
Housing
Epoxy-coated aluminum or 316L stainless; NEMA 4X, IP65

Order with option MLT in the gauge model code.

Two SurePoint magnetically actuated level switches with colour-coded leads

SurePoint™

Magnetic point-level switch

Leverless switch actuated by the float's magnet for high and low level alarms and basic control. No moving levers and no actuation power.

Contact
SPDT, latching
Rating
Up to 25 W resistive; 1 A at 24 VDC; 150 VDC · 230 VAC max
Hazardous area
Class I, Div. 1 (UL 1203); Class II, Groups E, F, G; gas groups confirmed at quotation
Switch temp.
−58 to +221 °F (−50 to +105 °C)
Housing
300-series stainless steel, factory sealed
Mounting
Band clamp; set point adjustable along the chamber

Order 1 to 8 switches with option PLS-1 to PLS-8.

Include LevelSync™ or SurePoint™ in the quotation

Hazardous-area certifications are held by Lamont's component manufacturing partner and apply to the supplied product. Final certification, temperature class and marking depend on configuration and are confirmed at quotation.

Data

Technical specifications

Ratings

PressureFull vacuum to 3,400 psig (234 bar)
Temperature−40 to +842 °F (−40 to +450 °C); lower temperatures on application review
Measuring rangeStandard lengths to 18.5 ft (222 in, 5,640 mm) centre-to-centre; longer lengths on request
AccuracyTypical ±0.4 in (±10 mm)
Specific gravity0.34 minimum

Construction

ConfigurationsSide–side (standard) · top–bottom · top–side · bottom–side · top-mount · custom dual-chamber on request (option X)
Chamber size1.5 in, 2 in; schedule and material per design. Special sizes on application review
Chamber constructionWelded 316 chamber with slip-on process flanges; internal float stop spring (bottom)
Chamber materialSS316 standard. Hastelloy, Monel K-500, Inconel 625, coated or lined: consult factory
Surface finishPassivated per ASTM A380 / A967 (standard) · electropolished, external surfaces, per ASTM B912 · painted · powder coated

Connections

Process connectionsFlanged; threaded (FNPT / MNPT); welded (Weldolet, Sockolet). ½ to 4 in NPS; DN15 to DN65; 15A to 50A
Flange classesANSI 150 to 1500 · DIN PN10 / 16 / 25 / 40 · JIS 5K to 20K (DIN and JIS special order) · other classes on request
Vent and drainThreaded ⅛ to 1 in; flanged ½ to 1 in; custom ports; or none

Indication

ScalesFeet and inches · metres / cm · percent · gallons or litres to tank volume · custom · none
Scale materialEtched aluminum, resistant to UV, abrasion and chemical attack; marking to MIL-STD-130N. Non-metallic scales optional

Codes, testing and documentation

Construction codeIndustrial grade (IG), ASME B31.1 (B1) or B31.3 (B3), specified in the model code
Pressure testPressure tested before shipment; hydrostatic test at not less than 1.5 × design pressure where specified; test reports available
Material traceabilityMaintained throughout manufacturing; MTRs available
NDEPer the governing code where required: visual examination, dye-penetrant examination of fillet welds, and positive material identification (PMI) where specified
Further inspectionAvailable on request

Options

FloatSense™ float-integrity monitoring (FS)A clear visual signal at the indicator if the float loses buoyancy and sinks, so a failed float is not read as a low level.
Insulation blanket (IB)Wraps the chamber; a clear window keeps the indicator readable.
Heat tracing (HT)Freeze protection for cold-climate service.
Interface service (INT)Float set for the second liquid's SG, specified in the model code.
Custom options (X)Special accessories engineered to the application, on request.
  • Ratings. Pressure and temperature ratings depend on materials, connections and configuration, and are confirmed at quotation.
  • Custom configurations. Non-standard lengths, exotic alloys and special process connections on request. Contact Lamont Controls Engineering.

Quality

Quality, testing and documentation

  1. 01

    Approval drawing

    Issued after the purchase order. The design is confirmed on the drawing before fabrication starts.

  2. 02

    Material

    Material traceability is maintained throughout manufacturing.

  3. 03

    Construction code

    Built to ASME B31.1 or B31.3, or industrial grade, as specified in the model code.

  4. 04

    NDE

    Per the governing code where required: visual examination, dye-penetrant examination of fillet welds, and positive material identification (PMI) where specified.

  5. 05

    Pressure test

    Pressure tested before shipment; hydrostatic test at not less than 1.5 × design pressure where specified.

  6. 06

    Float and indicator

    The float is weighted for the fluid’s specific gravity. The indicator and scale mount outside the chamber.

Documents

Material test reports (MTRs)
Available
Hydrostatic test reports
Available
Approval drawing
Issued after the purchase order
Certificate of origin
Chamber-of-commerce certified, on request
Further inspection
Available on request

Quotation

Request a quotation

Complete the process conditions below, or attach a datasheet or drawing. Fields marked * are required. Process data speeds up the quotation.

For a general enquiry, select Quick message and provide your contact details with a brief note.

For a replacement, attach a photo of the existing nameplate and enter the centre-to-centre dimension.

Alternatively, complete the fillable quote request form (PDF) and return it by email.

What happens nextLamont Controls Engineering reviews the conditions and replies within 1 to 3 business days with a quotation.

1-833-7LAMONT info@lamontcontrols.com

Provide your contact details and a brief message. Lamont Controls Engineering replies within 1 to 3 business days.

Attach the datasheet, drawing or P&ID and enter your contact details. Lamont Controls Engineering takes the conditions from the file and replies with a quotation or with questions.

A datasheet, drawing, P&ID or nameplate photo can replace the gauge fields: attach it and they become optional.

Process data (optional, speeds up the quotation)

Contact

Submissions are reviewed by Lamont Controls Engineering.By sending this form you agree to the Terms of use. See the Privacy policy.

Downloads

Documentation

Document access

Enter your business email address to download the product brochure, technical specification sheet and model code reference.

Your email address is used for communications related to this request. You may unsubscribe at any time. Lamont Controls Inc., 800–120 Eglinton Ave E, Toronto, ON M4P 1E2, Canada · info@lamontcontrols.com.

Cover of MM-BR-011, Magnamont product brochure, November 2026MM-BR-011 · NOVEMBER 2026Product brochure15 pages · 2.3 MB PDFDownload
Cover of MM-TS-010, Magnamont technical specification sheet, November 2026MM-TS-010 · NOVEMBER 2026Technical specification sheet2 pages · 314 KB PDFDownload
Cover of MM-MC-010, Magnamont model code reference, November 2026MM-MC-010 · NOVEMBER 2026Model code reference3 pages · 481 KB PDFDownload
Cover of LC-QR-010, the fillable MLG quote request formLC-QR-010 · NOVEMBER 2026Quote request form1 page · 82 KB · fillable PDFDownload
Outline drawing sheet, Magnamont, sent on requestOn request
LAMONT CONTROLS ENGINEERING · SENT AFTER REVIEWDimensional drawingsOutline drawings for the standard Magnamont™ configurations, one sheet each: side–side, top–bottom, top–side, bottom–side and top-mount. Sent by Lamont Controls Engineering after review; final dimensions are on the approval drawing, issued after the purchase order.
Request drawings

Guides. How to specify a magnetic level gauge · Installation best practices · Troubleshooting

Applications

Selected projects

Customer names withheld

Applications

Industries served

Nuclear power

Balance-of-plant condensate, feedwater and auxiliary tanks, with material traceability maintained throughout manufacturing.

Nuclear balance of plant

Power generation and steam

Condensate receivers, boiler feedwater tanks and hotwells, with ASME B31.1 construction options.

Deaerators and boiler feed tanks

Oil, gas and terminals

Sour water, odorant, propane and refined-fuel tanks, with heat tracing for cold climates.

Produced water · LPG and propane

Hydrogen and industrial gases

Liquid level in hydrogen and industrial-gas plants, documented for new-build projects.

Chemical and petrochemical

Solvents, caustics and hydrocarbons in day tanks, mixing vessels and batch reactors.

Chemical storage tanks

Marine and shipboard

Fuel, ballast, potable-water and sewage tanks; glass-free for vibration and sea air.

Marine tanks

Transformer and dielectric oil

Conservator and oil-tank level, including full-vacuum oil processing.

Refrigeration and cold storage

Anhydrous ammonia receivers and surge drums, in sealed, glass-free construction.

LPG and propane

Pulp and paper

Condensate systems, liquor tanks and mill utilities in continuous steam service.

Water and wastewater

Filtration skids, surge tanks and chemical-feed systems in pressure service.

Chemical storage tanks

HVAC and facility utilities

Cooling-tower sumps, boiler rooms and generator day tanks, often with SurePoint™ switches.

OEM and equipment builders

Compressor packages, pump skids and boilers. One approved drawing covers repeat production runs.

Also serving food and beverage · airports and deicing · mining and metals · steel production · research facilities. For aggressive corrosives, see Polysight™; for extreme pressure and temperature, see Fortimag™.

Request a quotation Call