SN-100 side-mount float switch
Mounts in a flanged nozzle on the vessel wall at the alarm height. A 2 in Class 150 RF flange with a 41 mm float, which passes a 2 in Schedule 40 or 80 nozzle. One DPDT micro switch rated 10 A at 250 VAC.
Level transmitters
Level switches
Level bridles and chambers
Level bridlesBridles and external chambersSS316, engineered to orderRetrofits and spare parts
Product selection
Send the fluid, specific gravity, design pressure and temperature, and centre-to-centre dimension. Lamont Controls Engineering recommends the gauge.
Request a quotationDocumentationCookies on this site
Analytics, advertising cookies (including our ads on other sites) and session recording stay off unless you accept. These tools show how the site is used and which advertising brings enquiries, and let Google and Microsoft show our ads to past visitors on other sites. The choice can be changed at any time under Cookie settings at the foot of each page. Privacy policy
SnapTrip™ is a range of flanged float and displacer level switches for high and low level alarms on tanks and vessels, in three models: side-mount float, top-mount float and top-mount displacer. Wetted parts and the process flange are 316L stainless steel. The contact is a snap-action micro switch, DPDT or SPDT, in a weatherproof housing.
Weatherproof housings, IP65 or IP66 · ambient from −4 °F (−20 °C)
Product



Photographs, representative units. Nameplate and finish as supplied may differ.
Operation

Float switch. A float rides on the liquid. When the level reaches the switch point, the movement of the float operates a snap-action micro switch in the housing, outside the process. The side-mount switch is fitted at the alarm height; the top-mount switch hangs its float below the flange at the switch point.
Displacer switch. A displacer hangs below the switch head at the switch point. As the liquid covers the displacer, its apparent weight falls and the switch operates. The suspension length sets the switch point, so a switch on a top nozzle can alarm low in a deep vessel.
Product
Mounts in a flanged nozzle on the vessel wall at the alarm height. A 2 in Class 150 RF flange with a 41 mm float, which passes a 2 in Schedule 40 or 80 nozzle. One DPDT micro switch rated 10 A at 250 VAC.
Mounts on a 4 in Class 150 RF nozzle on the vessel top, with a 90 mm float. The switch point is 300 mm (11.8 in) below the flange as standard. One SPDT micro switch rated 15 A at 250 VAC.
Mounts on a 3 in Class 150 RF nozzle on the vessel top. A 76.3 mm displacer hangs at the switch point on a standard suspension length of 2,000 mm (78.7 in). One SPDT micro switch rated 15 A at 250 VAC.
On a magnetic level gauge. For alarm points on a Lamont magnetic level gauge, SurePoint™ clamp-on switches mount outside the gauge chamber and need no process connection.
Options
Forged 316L flange (ASTM A182) in place of the standard 316L plate flange (ASTM A240). Longer material lead time.
185 mm standard. Longer to suit the nozzle, on request.
300 mm (11.8 in) below the flange, standard.
2,000 mm (78.7 in) standard; the switch point is set to the order.
High or low level alarm, stated for each SN-300 displacer switch.
| Position | Code | Description |
|---|---|---|
| Model | SN-100 | SnapTrip™ side-mount float switch, 1 × DPDT |
| SN-200 | SnapTrip™ top-mount float switch, 1 × SPDT | |
| SN-300 | SnapTrip™ top-mount displacer switch, 1 × SPDT | |
| Connection | 20 · 40 · 30 | 2 in (SN-100) · 4 in (SN-200) · 3 in (SN-300), Class 150 RF |
| Flange | P · F | 316L plate, ASTM A240 (standard) · 316L forged, ASTM A182 |
| Length | mm | Insertion (SN-100), switch point below the flange (SN-200) or suspension length (SN-300) |
| Action | H · L | High or low level alarm (SN-300) |
Example: SN-300-30-P-2000-L. Fluid, specific gravity, operating pressure and temperature are stated on the order datasheet, not in the model code.
Data
| Specification | Side-mount float switch | Top-mount float switch | Top-mount displacer switch |
|---|---|---|---|
| Mounting | Side, in a nozzle on the vessel wall | Top | Top |
| Process connection | 2 in Class 150 RF flange | 4 in Class 150 RF flange | 3 in Class 150 RF flange |
| Flange material | 316L stainless steel plate (ASTM A240); forged 316L (ASTM A182) on request | ||
| Wetted parts | 316L stainless steel | ||
| Float or displacer | Float 41 × 100 mm | Float, 90 mm | Displacer 76.3 × 150 mm |
| Length | Insertion 185 mm; longer to suit the nozzle on request | Switch point 300 mm (11.8 in) below the flange, standard | Suspension 2,000 mm (78.7 in), standard; switch point to order |
| Switch | Snap-action micro switch, 1 × DPDT | Snap-action micro switch, 1 × SPDT | Snap-action micro switch, 1 × SPDT |
| Contact rating | 10 A at 250 VAC; 5 A at 30 VDC | 15 A at 250 VAC; 0.5 A at 125 VDC | 15 A at 250 VAC; 0.5 A at 125 VDC |
| Enclosure | Weatherproof, IP66 | Weatherproof, IP65 | Weatherproof, IP65 |
| Housing | Aluminum | Carbon steel and aluminum | Carbon steel and aluminum |
| Cable entry | ½ in NPT (F), by adapter | ¾ in NPT (F), by adapter | ¾ in NPT (F), by adapter |
| Process temperature, max. | 248 °F (120 °C) | ||
| Operating pressure, max. | 142 psig (9.8 bar) | ||
| Ambient temperature | −4 to 140 °F (−20 to 60 °C) | −4 to 176 °F (−20 to 80 °C) | −4 to 176 °F (−20 to 80 °C) |
| Specific gravity | Confirmed for each order from the fluid data | ||
| Location | Ordinary (non-hazardous) locations | ||
Nozzle bore. The float or displacer passes through the process nozzle, so the nozzle bore must be larger than it: 41 mm for the side-mount switch, 76.3 mm for the displacer and 90 mm for the top-mount float. Send the nozzle size and schedule with the request.
Service. For ordinary (non-hazardous) locations. Not for use as a boiler low-water cut-off or in a safety instrumented function.
Selection
| Switch | Suits | Consider |
|---|---|---|
| Side-mount float switch2 in nozzle | A flanged nozzle on the vessel wall at the alarm height. | One nozzle for each alarm point. The float must pass the nozzle bore. |
| Top-mount float switch4 in nozzle | A high level alarm near the vessel top, where no side nozzle is available. | One switch point, 300 mm (11.8 in) below the flange as standard. |
| Top-mount displacer switch3 in nozzle | A switch point low in a deep tank or sump, from a nozzle on the vessel top. | The suspension length and switch point are set to the vessel. State high or low alarm. |
| SurePoint™ clamp-on switchOn a magnetic level gauge | Alarm points on a Lamont magnetic level gauge. | Mounts outside the gauge chamber, with no process connection. SurePoint™ |
Enquiry
A complete request is quoted fastest. Send the available details; Lamont Controls Engineering will ask for the rest.
Quotation
Complete the fields below, or attach the datasheet, requisition or tag list: with a file attached, the switch fields are optional. Fields marked * are required for pricing.
For several switches, send one request with a tag number for each, or attach the tag list. For a general enquiry, select Quick message.
What happens nextLamont Controls Engineering reviews the request and replies with a quotation.
1-833-7LAMONT info@lamontcontrols.comQuestions
Three flanged switches for high and low level alarms: the SN-100 side-mount float switch on a 2 in Class 150 RF nozzle, the SN-200 top-mount float switch on a 4 in nozzle and the SN-300 top-mount displacer switch on a 3 in nozzle. Wetted parts are 316L stainless steel. For alarm points on a Lamont magnetic level gauge, SurePoint™ clamp-on switches mount on the gauge chamber instead.
A float switch operates when the float, riding on the liquid, reaches the switch point. A displacer switch hangs a displacer at the switch point; as the liquid covers it, its apparent weight falls and the switch operates. Hung from a top nozzle on a standard suspension length of 2,000 mm (78.7 in), a displacer places the switch point low in a deep vessel.
A snap-action micro switch. The side-mount float switch has one DPDT contact rated 10 A at 250 VAC and 5 A at 30 VDC. The top-mount float and displacer switches have one SPDT contact rated 15 A at 250 VAC and 0.5 A at 125 VDC.
The float or displacer passes through the process nozzle, so the nozzle bore must be larger than it: 41 mm for the side-mount switch, 76.3 mm for the displacer and 90 mm for the top-mount float. Send the nozzle size and schedule with the request.
The switch type and quantity, the nozzle size, flange class and schedule, the fluid, specific gravity, operating pressure and temperature, high or low alarm for each switch with the switch point, and the electrical load. Lamont Controls Engineering replies with a quotation.
Downloads