Acid tank level gauges For sulfuric and hydrochloric acid
Polysight™ magnetic level gauges are specified for sulfuric and hydrochloric acid in storage tanks, day tanks and batch systems, and for pickling acids, acid leach solutions and acid CIP solutions. Both acids are heavier than water. Lamont Controls builds each gauge with a sealed thermoplastic chamber and no glass, and a float weighted to the SG of the acid as stored. The ClearView™ indicator mounts outside the chamber, isolated from the process. SurePoint™ alarm switches and a LevelSync™ 4–20 mA transmitter clamp to the same chamber. Lamont states the wetted materials of each gauge; the buyer confirms them for the acid, its concentration and its temperature.
- Pressure, Polysight™
- 150 psigfull vacuum to 10 bar
- Temperature
- −4…+248 °F−20…+120 °C, by chamber and float
- Hydrochloric acid, 31.5 %
- SG 1.16typical, 60–68 °F (16–20 °C)
- Wetted materials
- CPVC · PVDFchamber; PTFE or PVDF float
The SG value is typical and sets the float weighting only. Ratings are confirmed at quotation.
Service conditions
Sulfuric and hydrochloric acid service
- Where Polysight™ is specified. Sulfuric and hydrochloric acid in storage tanks, day tanks and batch systems; pickling acids in metal finishing; acid leach solutions and electrolyte circuits in mining; HCl handling in chlor-alkali plants; acid CIP solutions in food and beverage plants. For caustics, hypochlorite and other treatment chemicals, see Chemical storage tanks.
- Heavy liquids. Both acids are well above SG 1.00. The float is weighted for the SG of the acid at its stored concentration and temperature (see the float note).
- Wetted materials. The chamber and the float are in contact with the acid. Polysight™ chambers are CPVC or PVDF; floats are PTFE, PVDF or polypropylene. With a standard non-metallic float, there is no metal in the wetted path.
- Compatibility. Lamont offers CPVC and PVDF chambers for acid service. The chamber is selected at quotation from the acid, its concentration and the operating temperature. Lamont states the wetted materials on the quotation and in the nameplate model code; the buyer confirms their compatibility with the acid, its concentration and its temperature.
- No glass. A sealed thermoplastic chamber replaces the sight glass. There is no glass to break under thermal shock or impact, and the level is read on the external indicator.
- Fumes and washdown. The PVC-housed IPVC-80 indicator is recommended where corrosive fumes surround the tank, and the sealed HS-80 for condensation, humidity or washdown.

Build options
Typical build for an acid tank level gauge
| Gauge line | Polysight™, thermoplastic, for corrosive service from full vacuum to 150 psig (10 bar). Custom or exotic chamber materials CC: consult factory |
|---|---|
| Chamber | 2 in CPVC CPVC (standard) or PVDF PVDF for aggressive or hot corrosive service; industrial grade thermoplastic fabrication IG with solvent- and fusion-bonded joints. Both chambers are offered for acid service; the chamber is selected at quotation from the acid, its concentration and the operating temperature. |
| Float | PTFE TF, standard in CPVC chambers, for hydrochloric acid and aggressive reducing service; low-pressure service. PVDF PV, standard in PVDF chambers, for aggressive and high-purity chemistry. Polypropylene PP, optional, for general corrosive service |
| Float SG | Weighted to the SG of the acid as stored; model code position 06, for example SG1.16 |
| Connections | Flanged ANSI 150 (standard), FNPT or MNPT; 1, 1½ or 2 in (3 in: consult factory). DIN PN10 and JIS 5K on request |
| Vent and drain | Threaded FNPT (standard) or MNPT; ½, ¾ or 1 in |
| Indicator | ClearView™ IPVC-80, PVC flags in a PVC housing, rated 176 °F (80 °C), recommended for corrosive fumes. IPVC-120 with scale, rated 248 °F (120 °C). HS-80, sealed, for condensation or washdown |
| Scale | Feet and inches, metres, percent, or gallons or litres graduated to the tank’s volume |
| Finish | Natural; painted on CPVC for outdoor and UV service. Paint is not available on PVDF |
| Alarms and signal | SurePoint™ latching SPDT switches PLS-1 to PLS-8; LevelSync™ MLT, 4–20 mA with HART®. Externally mounted and magnetically coupled; no wetted parts |
| Testing and documents | Pressure tested before shipment; hydrostatic test with clean water at not less than 1.5 × design pressure (1 hour minimum) and a 24-hour water-fill leak test where specified. Test certificates available. |
Pressure and temperature ratings depend on materials, connections and configuration, and are confirmed at quotation.
Products for this service
Polysight™Thermoplastic, for corrosive serviceTo 150 psig
SurePoint™Magnetic point-level switchSPDT, latching, 1 to 8 per gauge
LevelSync™Magnetostrictive level transmitter4–20 mA with HART®

Engineering note
Float weighting and temperature limits
Float weighting for a heavy acid
A float weighted for water rides high in a heavy acid, and the gauge reads high. Specify the SG of the acid at its stored concentration and temperature. It is entered in model code position 06 (for example SG1.16).
| Liquid | Strength | SG, about |
|---|---|---|
| Sulfuric acid | 93 % | 1.83 |
| Hydrochloric acid | 31.5 % | 1.16 |
| Water | – | 1.00 |
The table sets float weighting only; it is not a statement of material compatibility. SG changes with concentration: where a tank receives a different strength, the float is weighted for the SG of the acid the tank holds. The PTFE float reads liquids above SG 0.84 and the PVDF float above SG 0.79, so both acids are within the SG range of either float.

Chamber and float temperature limits
Each wetted part has a maximum temperature. Where a chamber and a float are paired, the lower limit governs. The PTFE float is for low-pressure service, so Lamont states the rating of the complete gauge with the quotation.
| Build | Chamber | Float | Governs |
|---|---|---|---|
| CPVC + PTFE (standard) | ~199 °F (~93 °C) | 248 °F (120 °C) | Chamber, ~199 °F |
| PVDF + PVDF (standard) | ~248 °F (~120 °C) | 212 °F (100 °C) | Float, 212 °F |
| CPVC + PP | ~199 °F (~93 °C) | 176 °F (80 °C) | Float, 176 °F |
Chamber limits are service-dependent. The temperature limits for each acid are confirmed at quotation.
Alarms and signal
High and low alarms and a 4–20 mA signal
SurePoint™ switches and a LevelSync™ transmitter are externally mounted and magnetically coupled to the gauge’s MagnaLine™ float through the chamber wall. They have no wetted parts, need no additional tank nozzle, and are fitted at the factory or in the field.
SurePoint™ point-level switches
For high and low level alarms and basic control. Each switch clamps to the chamber with an adjustable band clamp and is actuated by the float’s magnet at its set point.
| Contact | SPDT, latching |
| Rating | Up to 25 W resistive; 1 A at 24 VDC; 150 VDC · 230 VAC max |
| Switch temperature | −58 to +221 °F (−50 to +105 °C) |
| Housing | 300-series stainless steel, factory sealed |
| Order | 1 to 8 switches, option PLS-1 to PLS-8 |
LevelSync™ level transmitter
Continuous level from the same float, by magnetostrictive time-of-flight sensing. No moving parts and no routine recalibration.
| Output | 4–20 mA with HART®; Modbus RTU or DDA optional |
| Inherent accuracy | ±0.039 in (±1 mm) |
| Supply | 10.5–28 VDC, loop powered |
| Housing | Epoxy-coated aluminum (standard) or 316L stainless steel; NEMA 4X, IP65 |
| Order | Option MLT in the gauge model code |
Applications
Selected projects
Quotation
What to send for a quotation
- Acid and concentration, and the SG of the acid as stored.
- Operating and design temperature, including any heat tracing or sun exposure.
- Operating and design pressure: atmospheric or the tank’s design rating.
- Centre-to-centre distance, connection size and type (flanged or NPT) and configuration.
- Surroundings: corrosive fumes, washdown or outdoor UV, for the indicator and finish.
- Level points: high and low alarms, and a 4–20 mA signal if required.
- Replacing an existing gauge: a photo of the nameplate and the existing centre-to-centre. See Retrofits.
Questions
Frequently asked questions
Which chamber material is used for sulfuric or hydrochloric acid?
Lamont offers CPVC and PVDF chambers for acid service. The chamber is selected at quotation from the acid, its concentration and the operating temperature; the model code lists PVDF for aggressive or hot corrosive service. Lamont states the wetted materials; the buyer confirms their compatibility with the acid as stored.
Which float is used in hydrochloric acid?
PTFE, the standard float in a CPVC chamber. Lamont lists the PTFE float for hydrochloric acid and aggressive reducing service. It reads liquids above SG 0.84 and is rated to 248 °F (120 °C). The PTFE float is for low-pressure service, so Lamont states the rating of the complete gauge with the quotation. In a PVDF chamber, the standard float is PVDF.
Which SG is specified for sulfuric acid?
The SG of the acid at its stored concentration and temperature: for example about 1.83 for 93 % sulfuric acid. The SG is entered in model code position 06. A float weighted for water would read high in the acid.
Is there any metal in contact with the acid?
Not with a standard float. The chamber is CPVC or PVDF and the floats are PTFE, PVDF or polypropylene, so with a standard non-metallic float there is no metal in the wetted path. The indicator, switches and transmitter mount outside the chamber.
What are the pressure and temperature limits?
The chamber is rated from full vacuum to 150 psig (10 bar). The temperature limit is the lower of the chamber and float limits: about 199 °F (93 °C) for CPVC with a PTFE float, and 212 °F (100 °C) for PVDF with a PVDF float. Ratings are confirmed at quotation.
Can high and low alarms and a 4–20 mA signal be added?
Yes. SurePoint™ SPDT switches and a LevelSync™ transmitter are externally mounted and magnetically coupled to the same float. They have no wetted parts, need no additional tank nozzle, and are fitted at the factory or in the field.