Lamont Controls 1-833-7LAMONT Request a quotation Call

Cookies on this site

Analytics, advertising measurement and session recording stay off unless accepted. They show how the site is used and which advertising brings enquiries. The choice can be changed at any time under Cookie settings at the foot of each page. Privacy policy

Polysight gauges: grey CPVC chambers, red PVC indicator flags, Lamont nameplates and flanged side connections
Polysight™ · CPVC chamber, PVC flag indicator, flanged side connection

Acid tank level gauges For sulfuric and hydrochloric acid

Polysight™ magnetic level gauges are specified for sulfuric and hydrochloric acid in storage tanks, day tanks and batch systems, and for pickling acids, acid leach solutions and acid CIP solutions. Both acids are heavier than water. Lamont Controls builds each gauge with a sealed thermoplastic chamber and no glass, and a float weighted to the SG of the acid as stored. The ClearView™ indicator mounts outside the chamber, isolated from the process. SurePoint™ alarm switches and a LevelSync™ 4–20 mA transmitter clamp to the same chamber. Lamont states the wetted materials of each gauge; the buyer confirms them for the acid, its concentration and its temperature.

Pressure, Polysight™
150 psigfull vacuum to 10 bar
Temperature
−4…+248 °F−20…+120 °C, by chamber and float
Hydrochloric acid, 31.5 %
SG 1.16typical, 60–68 °F (16–20 °C)
Wetted materials
CPVC · PVDFchamber; PTFE or PVDF float

The SG value is typical and sets the float weighting only. Ratings are confirmed at quotation.

Service conditions

Sulfuric and hydrochloric acid service

  • Where Polysight™ is specified. Sulfuric and hydrochloric acid in storage tanks, day tanks and batch systems; pickling acids in metal finishing; acid leach solutions and electrolyte circuits in mining; HCl handling in chlor-alkali plants; acid CIP solutions in food and beverage plants. For caustics, hypochlorite and other treatment chemicals, see Chemical storage tanks.
  • Heavy liquids. Both acids are well above SG 1.00. The float is weighted for the SG of the acid at its stored concentration and temperature (see the float note).
  • Wetted materials. The chamber and the float are in contact with the acid. Polysight™ chambers are CPVC or PVDF; floats are PTFE, PVDF or polypropylene. With a standard non-metallic float, there is no metal in the wetted path.
  • Compatibility. Lamont offers CPVC and PVDF chambers for acid service. The chamber is selected at quotation from the acid, its concentration and the operating temperature. Lamont states the wetted materials on the quotation and in the nameplate model code; the buyer confirms their compatibility with the acid, its concentration and its temperature.
  • No glass. A sealed thermoplastic chamber replaces the sight glass. There is no glass to break under thermal shock or impact, and the level is read on the external indicator.
  • Fumes and washdown. The PVC-housed IPVC-80 indicator is recommended where corrosive fumes surround the tank, and the sealed HS-80 for condensation, humidity or washdown.
Polysight indicator at the liquid level, close up: white flags above, red flags below, in the transparent PVC housing
Indicator · PVC flags change from white to red at the level.

Build options

Typical build for an acid tank level gauge

Gauge linePolysight™, thermoplastic, for corrosive service from full vacuum to 150 psig (10 bar). Custom or exotic chamber materials CC: consult factory
Chamber2 in CPVC CPVC (standard) or PVDF PVDF for aggressive or hot corrosive service; industrial grade thermoplastic fabrication IG with solvent- and fusion-bonded joints. Both chambers are offered for acid service; the chamber is selected at quotation from the acid, its concentration and the operating temperature.
FloatPTFE TF, standard in CPVC chambers, for hydrochloric acid and aggressive reducing service; low-pressure service. PVDF PV, standard in PVDF chambers, for aggressive and high-purity chemistry. Polypropylene PP, optional, for general corrosive service
Float SGWeighted to the SG of the acid as stored; model code position 06, for example SG1.16
ConnectionsFlanged ANSI 150 (standard), FNPT or MNPT; 1, 1½ or 2 in (3 in: consult factory). DIN PN10 and JIS 5K on request
Vent and drainThreaded FNPT (standard) or MNPT; ½, ¾ or 1 in
IndicatorClearView™ IPVC-80, PVC flags in a PVC housing, rated 176 °F (80 °C), recommended for corrosive fumes. IPVC-120 with scale, rated 248 °F (120 °C). HS-80, sealed, for condensation or washdown
ScaleFeet and inches, metres, percent, or gallons or litres graduated to the tank’s volume
FinishNatural; painted on CPVC for outdoor and UV service. Paint is not available on PVDF
Alarms and signalSurePoint™ latching SPDT switches PLS-1 to PLS-8; LevelSync™ MLT, 4–20 mA with HART®. Externally mounted and magnetically coupled; no wetted parts
Testing and documentsPressure tested before shipment; hydrostatic test with clean water at not less than 1.5 × design pressure (1 hour minimum) and a 24-hour water-fill leak test where specified. Test certificates available.

Pressure and temperature ratings depend on materials, connections and configuration, and are confirmed at quotation.

Sample code: acid tank, CPVC chamber, PTFE float.PS-SS-CPVC-02-TF-SG1.15-150-IG-FL-01-IPVC-120-NF-IMP-120.0V-F-05-F-05-NTSide–side, 2 in CPVC chamber, PTFE float weighted for SG 1.15, ANSI 150 flanged 1 in connections, IPVC-120 indicator, feet-and-inches scale, 120 in centre-to-centre, ½ in FNPT vent and drain, natural finish. Position 03 sets the chamber, 05 the float and 06 the SG. The sample shows how the code reads; it is not a material recommendation for a specific acid.

Engineering note

Float weighting and temperature limits

Float weighting for a heavy acid

A float weighted for water rides high in a heavy acid, and the gauge reads high. Specify the SG of the acid at its stored concentration and temperature. It is entered in model code position 06 (for example SG1.16).

Typical SG at about 60 to 68 °F (16 to 20 °C)
LiquidStrengthSG, about
Sulfuric acid93 %1.83
Hydrochloric acid31.5 %1.16
Water–1.00

The table sets float weighting only; it is not a statement of material compatibility. SG changes with concentration: where a tank receives a different strength, the float is weighted for the SG of the acid the tank holds. The PTFE float reads liquids above SG 0.84 and the PVDF float above SG 0.79, so both acids are within the SG range of either float.

MagnaLine solid PTFE float for a Polysight gauge, upright with the magnet end at the top
MagnaLine™ PTFE float · The standard float in a CPVC chamber.

Chamber and float temperature limits

Each wetted part has a maximum temperature. Where a chamber and a float are paired, the lower limit governs. The PTFE float is for low-pressure service, so Lamont states the rating of the complete gauge with the quotation.

Polysight™ wetted parts, maximum temperature
BuildChamberFloatGoverns
CPVC + PTFE (standard)~199 °F (~93 °C)248 °F (120 °C)Chamber, ~199 °F
PVDF + PVDF (standard)~248 °F (~120 °C)212 °F (100 °C)Float, 212 °F
CPVC + PP~199 °F (~93 °C)176 °F (80 °C)Float, 176 °F
Example. At 140 °F (60 °C), the service is within the temperature limit of every pairing above. At 205 °F (96 °C), it is above the CPVC chamber limit; of the pairings above, only the PVDF chamber with a PVDF float, rated to 212 °F (100 °C), is within its temperature limits. These are temperature limits only; the materials are confirmed for the acid separately.

Chamber limits are service-dependent. The temperature limits for each acid are confirmed at quotation.

Alarms and signal

High and low alarms and a 4–20 mA signal

SurePoint™ switches and a LevelSync™ transmitter are externally mounted and magnetically coupled to the gauge’s MagnaLine™ float through the chamber wall. They have no wetted parts, need no additional tank nozzle, and are fitted at the factory or in the field.

SurePoint™ point-level switches

For high and low level alarms and basic control. Each switch clamps to the chamber with an adjustable band clamp and is actuated by the float’s magnet at its set point.

ContactSPDT, latching
RatingUp to 25 W resistive; 1 A at 24 VDC; 150 VDC · 230 VAC max
Switch temperature−58 to +221 °F (−50 to +105 °C)
Housing300-series stainless steel, factory sealed
Order1 to 8 switches, option PLS-1 to PLS-8

SurePoint™ specifications

LevelSync™ level transmitter

Continuous level from the same float, by magnetostrictive time-of-flight sensing. No moving parts and no routine recalibration.

Output4–20 mA with HART®; Modbus RTU or DDA optional
Inherent accuracy±0.039 in (±1 mm)
Supply10.5–28 VDC, loop powered
HousingEpoxy-coated aluminum (standard) or 316L stainless steel; NEMA 4X, IP65
OrderOption MLT in the gauge model code

LevelSync™ specifications

Applications

Selected projects

Customer names withheld

Quotation

What to send for a quotation

  1. Acid and concentration, and the SG of the acid as stored.
  2. Operating and design temperature, including any heat tracing or sun exposure.
  3. Operating and design pressure: atmospheric or the tank’s design rating.
  4. Centre-to-centre distance, connection size and type (flanged or NPT) and configuration.
  5. Surroundings: corrosive fumes, washdown or outdoor UV, for the indicator and finish.
  6. Level points: high and low alarms, and a 4–20 mA signal if required.
  7. Replacing an existing gauge: a photo of the nameplate and the existing centre-to-centre. See Retrofits.

Questions

Frequently asked questions

Which chamber material is used for sulfuric or hydrochloric acid?

Lamont offers CPVC and PVDF chambers for acid service. The chamber is selected at quotation from the acid, its concentration and the operating temperature; the model code lists PVDF for aggressive or hot corrosive service. Lamont states the wetted materials; the buyer confirms their compatibility with the acid as stored.

Which float is used in hydrochloric acid?

PTFE, the standard float in a CPVC chamber. Lamont lists the PTFE float for hydrochloric acid and aggressive reducing service. It reads liquids above SG 0.84 and is rated to 248 °F (120 °C). The PTFE float is for low-pressure service, so Lamont states the rating of the complete gauge with the quotation. In a PVDF chamber, the standard float is PVDF.

Which SG is specified for sulfuric acid?

The SG of the acid at its stored concentration and temperature: for example about 1.83 for 93 % sulfuric acid. The SG is entered in model code position 06. A float weighted for water would read high in the acid.

Is there any metal in contact with the acid?

Not with a standard float. The chamber is CPVC or PVDF and the floats are PTFE, PVDF or polypropylene, so with a standard non-metallic float there is no metal in the wetted path. The indicator, switches and transmitter mount outside the chamber.

What are the pressure and temperature limits?

The chamber is rated from full vacuum to 150 psig (10 bar). The temperature limit is the lower of the chamber and float limits: about 199 °F (93 °C) for CPVC with a PTFE float, and 212 °F (100 °C) for PVDF with a PVDF float. Ratings are confirmed at quotation.

Can high and low alarms and a 4–20 mA signal be added?

Yes. SurePoint™ SPDT switches and a LevelSync™ transmitter are externally mounted and magnetically coupled to the same float. They have no wetted parts, need no additional tank nozzle, and are fitted at the factory or in the field.

Request a quotation Call